200,000:1 native contrast
Deep blacks keep dark dashboards and night-vision feeds readable without raising brightness.
COB Fine Pitch
The command-centre benchmark: P0.9 COB with 200,000:1 contrast and a sealed front for continuous operation.
0.93mm
Pixel pitch
600 / 1,000 nits
Brightness
>7680Hz
Refresh rate

P0.9 is the most specified COB pitch for command centres and network operations rooms. It balances fine detail with a cabinet cost that stays practical across a 200m² video wall, and the dual brightness option covers both dim control rooms and daylit briefing areas.
Every unit is assembled and tested in Shenzhen before packing. Cabinet drawings, pixel map and control-system settings are supplied with the shipment, so the configuration on site matches the quotation.
Specifications
Engineering decisions behind COB P0.9, and what they change on site.
Deep blacks keep dark dashboards and night-vision feeds readable without raising brightness.
600 or 1,000 nits can be specified per project without changing cabinet or control hardware.
Power and driver layout is built for continuous operation, with front-service access for spares.
COB P0.9
COB P0.9 is built on a COB module in which the RGB chips are bonded directly to the board and sealed as one surface. The 600 × 337.5 × 39mm cabinet carries the module, driver and power supply as a front-service unit.
The LED die and wire bonds are encapsulated in a protective layer. There is no exposed lamp to catch a cloth or a fingernail, which matters in busy lobbies and control rooms.
Flip-chip mounting improves heat transfer from the die to the PCB and supports the high contrast and low power figures quoted for the series.
Driver ICs and the power supply sit behind the module on a serviceable carrier, separated from the display face.
The machined frame holds the module plane flat and provides the datum for adjacent cabinets, keeping seams consistent across a large wall.
The decisions that affect how COB P0.9 looks, installs and stays serviceable on site.
The black encapsulant and deep module structure reduce reflections, so dark content stays black under room lighting.
The COB surface can be cleaned without exposing lamps. This suits menu boards, reception walls and spaces with daily handling.
Common-cathode drive lowers power and heat compared with standard drive, which reduces running cost on walls that stay on all day.
Cabinet flatness is checked before packing and the wall is planned from the cabinet datum, not from the visible module edge.
Service is planned before the wall is built. Modules, cards and power supplies are replaced from the access direction agreed on the drawing.
The module is released from the front with a service tool. There is no rear clearance requirement, so the wall can sit close to a finished surface.
The sealed COB face is cleaned with a soft cloth and approved cleaner. There are no exposed lamps or masks to dislodge.
Replacement modules are matched to the original batch. The calibration file and spare module list are supplied with the project.
Product credibility
COB P0.9 is built on the same production line as our project walls. Cabinets, modules and control settings are recorded per batch, and the documentation travels with the shipment so the site team is not working from memory.
ISO 9001
Factory process control
CE / RoHS / FCC
Product compliance
Batch tested
Aging and calibration record
2–3 years
Standard warranty
COB selection and delivery
The right COB pitch is set by the closest viewer, the amount of ambient light and how long the wall runs each day. Use the three checks below before comparing price per square metre.
For control rooms and executive rooms, the front row usually sits 3–6 m away. P0.9–P1.25 keeps text and data legible there; P1.56–P1.9 is enough when the nearest viewer is beyond 6 m.
COB is specified where ceiling lights, windows or glass partitions would wash out a standard panel. The sealed matte face and deep black structure protect dark content in bright rooms.
A wall fixed close to a finished surface needs front service. Confirm the recess depth, cabinet format and whether the receiving card and power supply can be reached from the aisle.
Model comparison
Pitch, power, cabinet and the job each model is specified for. Open a model to see its cabinet build, service access and quotation route.
| Model | Brightness | Avg power | Cabinet | Specified for | Detail |
|---|---|---|---|---|---|
COB P0.7 0.78mm | 600 nits | ≤200 W/m² | 600 × 337.5 × 39mm | Control rooms · Command centres | View model |
COB P0.9Current 0.93mm | 600 / 1,000 nits | ≤200 W/m² | 600 × 337.5 × 39mm | Command centres · Network operations | Selected |
COB P1.25 1.25mm | 600 / 1,000 nits | ≤250 W/m² | 600 × 337.5 × 39mm | Boardrooms · Corporate lobbies | View model |
COB P1.56 1.56mm | 600 / 1,000 nits | ≤250 W/m² | 600 × 337.5 × 39mm | Meeting rooms · Exhibition stands | View model |
COB P1.9 1.86mm | 600 / 1,000 nits | ≤280 W/m² | 600 × 337.5 × 39mm | Glazed atriums · Public halls | View model |
Typical values for the current series. Final brightness, power and cabinet detail are confirmed on the approved specification sheet.
Deployment playbook
COB is not the default answer for every indoor wall. These are the conditions where its contrast, sealed surface and thermal behaviour change the result on site.
Data, maps and camera feeds run continuously. A low-reflectance surface keeps dark backgrounds readable under task lighting, while front service avoids a rear plant room.
P0.9–P1.25 · 600–1,000 nits · 24/7 thermal plan
The wall is viewed from a table, photographed on video calls and must stay quiet. Fine pitch, camera-safe refresh and fanless cabinet options matter more than peak brightness.
P1.25–P1.56 · >7680Hz · low-noise drive
The surface is cleaned, touched and exposed to daily light. The sealed COB face can be wiped without exposing lamps, and high contrast keeps food photography readable.
P1.25–P1.9 · IP65 front · easy-clean surface
Delivery control
COB walls are assembled as cabinets, not loose modules. The factory record follows the shipment so the site team can match cabinet positions, spare modules and control settings.
Handover pack
Cabinet layout, control points, power distribution and the service direction are fixed before materials are cut. The approved drawing becomes the reference for every later check.
LED modules, driver ICs and power supplies are drawn from the same production batch where the order size allows, then labelled by cabinet position.
Assembled cabinets run through an aging cycle and white-balance calibration. Faults found at this stage are corrected before packing, not after arrival.
Cabinets are packed against the transport method and site access. Each box is marked with its wall position and the cabinet drawing is included in the handover pack.
Buyer questions
These are the points that most often change the specification after the first enquiry. If your question is not here, send it with the site details.
Ask an engineerCOB usually gives a calmer black surface and a more sealed front, which helps in rooms with windows and ceiling lights. SMD can still be appropriate where the room is controlled, the viewing distance is longer and the budget is tighter.
P0.9 is normally specified for a closest viewing distance of about 3 m. If the front row is closer, P0.7 should be reviewed; if the nearest viewer is beyond 4–5 m, P1.25 may deliver the same perceived result at a lower cost.
Yes. The sealed front is cleaned with a soft cloth and an approved cleaner. Abrasive pads and solvent cleaners are avoided, and the cleaning method is included in the handover pack.
Standard COB models are typically 5–7 working days after drawing approval and deposit. Custom cabinet formats, mixed batches or project-specific control requirements are confirmed on the quotation.
Next step
Use these pages to compare technologies, check installed references and prepare the information needed for a quotation.
See how this series is specified against viewing distance, room light and installation constraints.
Open application guideReview project types, cabinet formats and the delivery scope used on comparable installations.
View case studiesRequest the current specification sheet, cabinet drawing and control compatibility list.
Open downloadsSend the wall size, viewing distance and site photos. We reply with a configuration and quotation.
Request a quoteSend viewing distance, wall size and installation type. We reply with cabinet quantity, control layout and a quotation within 24 business hours.