Transparent LED Display Series

Transparent LED Display Series

Turn glass into media without blocking daylight.

Crystal film · Holographic · Standard transparent

Turn glass into a media surface without blocking daylight. Three transparent routes cover storefront film, holographic showpieces and standard indoor or outdoor curtains, all supplied factory-direct with control and structure guidance.

Up to 95%

Transparency on crystal film

1–3mm

Film thickness, no steel frame

P2.5–P20

Pitch range across the series

Choose by glass, viewing distance and brightness

All three routes share the same control platform and can be combined in one project.

Series performance

Pitch range and the job each sub-series is specified for.

SeriesPitchSpecified for
Crystal Film ScreenP4–P20 · up to 95% transparencySelf-adhesive film, 3 mm thin, applied directly to existing glass.
Holographic Transparent ScreenP2.5–P6.25 · 80–90% transparencySuspended LED mesh for floating images in retail and exhibitions.
Standard Transparent ScreenP2.6–P15.6 · 75–90% transparencyAluminum-framed panels for windows, atriums and facades.

Transparent LED Display Series

Structure introduction

transparent LED display uses a framed transparent cabinet. An aluminium frame carries the LED modules, power supply and receiving card while leaving the centre of each cabinet open.

Series specification
01

Aluminium frame

The frame carries the load and provides mounting points for wall, atrium or facade installation.

02

Transparent module field

LED modules are arranged on a transparent substrate, keeping a percentage of the panel open to light.

03

Power and control chamber

Power supplies and receiving cards sit in a protected chamber within the frame, accessible for service.

04

Sealed outdoor option

Outdoor versions add sealing and a weather-rated rear cover for facade and atrium installations.

Design details

The decisions that affect how Transparent LED Display Series looks, installs and stays serviceable on site.

01

Transparency and brightness balance

The open area and LED package are selected for the background and viewing distance, so the screen does not read as a dark panel.

02

Cabinet depth

The frame depth is kept compact for window and atrium installations where clearance is limited.

03

Seam planning

Cabinet datums are set from the frame, keeping the module grid aligned across a large transparent wall.

04

Service access

Modules and electronics are reachable from the front or rear depending on the mounting condition.

Front maintenance

Service is planned before the wall is built. Modules, cards and power supplies are replaced from the access direction agreed on the drawing.

Front-service module design

Front or rear module access

Service direction is agreed at design stage. Where rear access is impossible, front-service modules are specified.

Power and card replacement

Receiving cards and power supplies are field-replaceable units within the frame chamber.

Seal and cleaning checks

Outdoor installations include gasket inspection and a cleaning procedure that protects the transparent substrate.

Product credibility

Documented before it ships

Transparent LED Display Series is built on the same production line as our project walls. Cabinets, modules and control settings are recorded per batch, and the documentation travels with the shipment so the site team is not working from memory.

ISO 9001

Factory process control

CE / RoHS / FCC

Product compliance

Batch tested

Aging and calibration record

2–3 years

Standard warranty

Quality record

  • CE, RoHS and FCC documentation for the supplied configuration.
  • Aging and white-balance calibration record per batch.
  • Cabinet drawing, pixel map and control settings in the handover pack.
  • Spare modules matched to the original production batch.

Transparent series selection

Choose the transparent route by the glass

Crystal film, holographic mesh and framed transparent cabinets solve different site conditions. Start with the glass or opening, then set transparency and brightness against the background.

01Film · mesh · framed cabinet

Existing glass or new opening

Crystal film bonds to existing glass and adds almost no depth. Holographic mesh is suspended for a floating layer. Standard transparent cabinets provide a framed structure for larger or outdoor openings.

0275–95% transparency

Balance transparency and brightness

A high-transparency film keeps daylight and sightlines but has less brightness headroom. A framed cabinet gives more output for facades and atriums where the background is bright.

03Remote control location

Find the controller and power route

The controller and power supply are located off the display surface. Confirm the cable path, access panel and whether the route can be hidden behind a mullion or ceiling.

Model comparison

Compare Transparent LED Display Series models

Pitch, power, cabinet and the job each model is specified for. Open a model to see its cabinet build, service access and quotation route.

Ask for a model recommendation
ModelBrightnessAvg powerCabinetSpecified forDetail
Crystal Film P6.25

6.25mm

4,500 nits≤180 W/m²Film roll, cut to glassShop windows · Bank branchesView model
Crystal Film P10

10mm

4,000 nits≤150 W/m²Film roll, cut to glassGlass facades · Bank branchesView model
Holographic P3.9

3.9mm

1,500–8,000 nits≤260 W/m²Hanging mesh, 500 × 500mmRetail launches · ExhibitionsView model
Holographic P6.25

6.25mm

1,500–8,000 nits≤220 W/m²Hanging mesh, 500 × 1000mmAtrium suspensions · Window displaysView model
Standard Transparent P3.91–7.8

3.91–7.8mm

5,500 nits≤280 W/m²500 × 500 / 500 × 1000mmBuilding facades · Atrium wallsView model
Standard Transparent P5.2–10.42

5.2–10.42mm

5,000 nits≤240 W/m²500 × 1000mmShop windows · Interior partitionsView model
Standard Transparent P10.42

10.42mm

5,000 nits≤200 W/m²500 × 1000mmGlass facades · Atrium glazingView model

Typical values for the current series. Final brightness, power and cabinet detail are confirmed on the approved specification sheet.

Deployment playbook

Three transparent routes in context

The same glass can require a film, a suspended mesh or a framed curtain depending on depth, background and structural support.

01

Retail windows

The shopfront must stay open to the street. Crystal film preserves daylight and sightlines while adding a media layer to existing glass.

Crystal film · P6.25–P10 · 90–95% transparency

02

Atriums and showrooms

A suspended mesh creates a floating image without blocking the architecture behind. Rigging points and sightlines are planned together.

Holographic · P3.9–P6.25 · 80–90% transparency

03

Facades and transport hubs

A framed cabinet gives a stable structure across a large opening. Outdoor versions add sealing and a weather-rated rear cover.

Standard transparent · P2.6–P15.6 · IP65 option

Delivery control

Transparent project sequence

Transparent displays are sensitive to the glass survey, mounting method and background. The project starts with a site check rather than a cabinet list.

Handover pack

  • Approved cabinet layout and pixel map
  • Control settings and calibration record
  • Packing list, spare list and service notes
Request the current datasheet
  1. 1

    Freeze the drawing

    Approved layout, pixel map and power schedule

    Cabinet layout, control points, power distribution and the service direction are fixed before materials are cut. The approved drawing becomes the reference for every later check.

  2. 2

    Match the batch

    Batch record and module position list

    LED modules, driver ICs and power supplies are drawn from the same production batch where the order size allows, then labelled by cabinet position.

  3. 3

    Age and calibrate

    Aging log and calibration file

    Assembled cabinets run through an aging cycle and white-balance calibration. Faults found at this stage are corrected before packing, not after arrival.

  4. 4

    Pack for the route

    Packing list, spare list and handover pack

    Cabinets are packed against the transport method and site access. The handover pack includes the glass survey notes, controller location and cleaning procedure for the transparent surface.

Buyer questions

Questions we answer before quotation

These are the points that most often change the specification after the first enquiry. If your question is not here, send it with the site details.

Ask an engineer
01Can all three transparent routes share one control system?

They can share a compatible control platform when the receiving cards and playback system are specified together. This is useful where a project combines a film window with a framed atrium wall.

02Does transparency reduce brightness?

Yes. A more open pixel grid lets more background through but leaves less area for light output. The specification balances transparency, brightness and viewing distance for the actual site.

03Which route works on existing glass?

Crystal film is designed for existing glass. Holographic mesh and framed cabinets need a frame or suspension structure, so they are used where the opening or ceiling can support the installation.

04Can transparent displays be used outdoors?

Standard transparent cabinets have an IP65 outdoor option. Film and holographic routes are usually indoor or semi-outdoor; the exposure and cleaning plan are confirmed during the survey.

Send us a photo of your glass

Tell us the glass width, height and indoor or outdoor exposure. We will confirm the route, pitch and mounting method.

粤ICP备2026050467号-1