Primary structure
A steel or aluminium frame carries the display and transfers wind and self-weight to the building or foundation. The section is selected from the installation height and site load.
Creative LED Display Series
Street-level media built into the pole.
P1.86–P3.846 · 3–12 m · double-sided or 360°
A street-light pole with integrated LED panels for roadside advertising, community notices and smart-city information. The structure is calculated for wind load and supplied with a maintenance access door.
To drawing
Structure engineered per site
Wind-load
Calculated for the installation height
Pixel mapping
Content mapping supplied with the build

Display, power and pole arrive as one engineered assembly.
5,000–7,000 nits stays readable in daylight.
4G or LAN control for scheduled advertising and notices.
Lockable door for power and control maintenance.
Light Pole LED Screen
Light Pole LED Screen is engineered around the site rather than a standard cabinet grid. The structure, module layout and mounting points are produced from a drawing that fixes the shape, viewing direction and access route.
A steel or aluminium frame carries the display and transfers wind and self-weight to the building or foundation. The section is selected from the installation height and site load.
Modules are arranged to the drawing, with cut modules and edge details planned so the visible shape matches the design.
Power supplies and receiving cards sit in a protected enclosure with a service route that does not disturb the visible surface.
Base plate, wall bracket or suspension points are detailed for the actual structure, including access for adjustment after installation.
The decisions that affect how Light Pole LED Screen looks, installs and stays serviceable on site.
The display is not forced into a rectangular cabinet grid. The outline, radius and edge treatment follow the approved drawing.
Module orientation and brightness are set for the direction people actually approach the installation.
A pixel map is supplied so artwork can be produced for the exact shape without stretching or guessing the active area.
Access panels and removable modules are planned before fabrication, so maintenance does not require dismantling the artwork.
Service is planned before the wall is built. Modules, cards and power supplies are replaced from the access direction agreed on the drawing.
Service panels are located on the least visible face. Modules and electronics are reached without removing the whole installation.
Replacement modules are supplied to the project drawing. The pixel map identifies the exact position for the replacement.
Outdoor and pole-mounted units include a fixing and structure inspection schedule in the handover pack.
Product credibility
Light Pole LED Screen is built on the same production line as our project walls. Cabinets, modules and control settings are recorded per batch, and the documentation travels with the shipment so the site team is not working from memory.
ISO 9001
Factory process control
CE / RoHS / FCC
Product compliance
Batch tested
Aging and calibration record
2–3 years
Standard warranty
Municipal and commercial media along streets.
Public information, air quality and alerts.
Wayfinding and event notices.
Forecourt promotion at eye level.
Each model links to its cabinet, specification and installation notes.
Light pole selection
A light pole display is an outdoor structure with a screen attached. Pole height, road position, wind load and foundation decide the build before brightness is discussed.
A 3–5 m pole suits pedestrian and forecourt viewing; 6–12 m poles serve roadways and plazas. The display height and tilt are set from the traffic and pedestrian approach.
Double-sided panels serve two directions of traffic. A 360° layout is used where people approach from multiple sides. The cabinet and power distribution follow the chosen layout.
The pole, base and anchor detail are reviewed against the site wind load. The foundation and access door are part of the delivery, not an afterthought.
Deployment playbook
The same pole family can serve commercial advertising, municipal information and campus wayfinding with different control and content plans.
The display faces traffic and runs scheduled campaigns. High brightness, remote publishing and a lockable service door are the base requirements.
P2.56–P3.846 · 5,000–7,000 nits · 4G control
Public messages, alerts and environmental data share the screen. The control platform supports scheduled and remote content.
P1.86–P3.125 · IP65 · remote management
Wayfinding and event notices are viewed at walking pace. A lower-height pole and a clear content hierarchy are preferred.
P1.86–P2.56 · 3–6 m pole · pedestrian viewing
Delivery control
The pole is fabricated with the display, power and control integrated. The foundation drawing and lifting points are issued before shipment.
Handover pack
Cabinet layout, control points, power distribution and the service direction are fixed before materials are cut. The approved drawing becomes the reference for every later check.
LED modules, driver ICs and power supplies are drawn from the same production batch where the order size allows, then labelled by cabinet position.
Assembled cabinets run through an aging cycle and white-balance calibration. Faults found at this stage are corrected before packing, not after arrival.
Cabinets are packed against the transport method and site access. The packing list includes the foundation template, anchor set and commissioning checklist.
Buyer questions
These are the points that most often change the specification after the first enquiry. If your question is not here, send it with the site details.
Ask an engineerThe foundation design and anchor template are included, while the civil work is completed locally. The drawing is issued for the site conditions before fabrication.
The pole can use 4G, Wi-Fi or LAN control depending on the site. Content can be scheduled remotely, and the control hardware is located behind the lockable service door.
Yes. Double-sided and 360° layouts are available. The power and control distribution are designed for the selected layout.
Wind load is set by the installation location and height. The pole and foundation are reviewed against the project requirement, and the final calculation is included in the drawing package.
Next step
Use the outdoor media guide and references to confirm pole height, foundation and control.
See how this series is specified against viewing distance, room light and installation constraints.
Open application guideReview project types, cabinet formats and the delivery scope used on comparable installations.
View case studiesRequest the current specification sheet, cabinet drawing and control compatibility list.
Open downloadsSend the wall size, viewing distance and site photos. We reply with a configuration and quotation.
Request a quoteTell us the pole height and road position. We will provide a structure drawing.