Rental LED Display · Product Series
Rental LED, tour-ready and camera-safe in minutes.
P2.6 · P2.9 · P3.91 · P4.81
Quick-lock die-cast cabinets built for repeated transport and fast rigging. Curved locks, flight-case packing and front/rear service keep changeover time short on tour and on site.
P2.6–P4.81
Pitch range for touring and events
>7680Hz
Refresh for camera and broadcast
500×500mm
Fast-lock cabinet and flight cases

Models



Rental P3.91
3.91mm- Brightness
- 5000 nits
- Avg power
- ≤280 W/m²
- Cabinet size
- 500×500 / 500×1000mm

Rental P4.81
4.81mm- Brightness
- 5500 nits
- Avg power
- ≤300 W/m²
- Cabinet size
- 500×500 / 500×1000mm
Advantages
Quick-lock assembly
Tool-free locking for fast stage builds.
Curved configuration
Optional curved locks for 3D stage shapes.
Flight-case ready
Cabinets and accessories packed for touring.
Front & rear service
Access modules from either side on site.
Rental LED Display
Structure introduction
rental LED display is assembled as a touring cabinet, not an installed panel. A die-cast magnesium frame carries the LED modules, receiving card and power supply as one locked unit, so the 500 × 500 / 500 × 1000mm cabinet can be handled, flown and struck repeatedly without losing alignment.
Load-bearing die-cast frame
Ribs are cast into the cabinet rather than added as separate brackets. The frame keeps the module plane flat under truss load and protects the corners during freight.
Module and driver bay
LED modules seat into machined pockets. The receiving card and power supply sit behind a removable rear cover, separated from the module face so heat does not pass through the LED board.
Lock and alignment system
Tool-free locks and locating pins pull adjacent cabinets to a controlled seam. Curved locks are available for concave or convex stage shapes without changing the cabinet family.
Power and data path
Power and data connectors are recessed into the frame and rated for repeated mating. Cabinets can be fed from either side to suit truss layout and flight-case order.
Design details
The decisions that affect how Rental LED Display looks, installs and stays serviceable on site.
Seam control at stage distance
The module plane and lock datum are machined together, so a 4 × 3m wall keeps a consistent seam instead of tightening at the centre and opening at the edges.
Rigging without extra steel
Top and bottom attachment points accept standard clamps and hooks. The cabinet weight of 7.5–12.5kg is kept within two-person handling for changeovers.
Front and rear service
Modules can be removed from the front when the wall is tight to a set, while cards and power supplies are reached from the rear when the wall is flown.
Road-case thinking
Connector recesses, corner protection and a shared flight-case footprint reduce damage during load-in and keep spare logistics simple across a tour.
Front maintenance
Service is planned before the wall is built. Modules, cards and power supplies are replaced from the access direction agreed on the drawing.
Front module replacement
A service tool releases the module from the face. Replacement modules are batch-matched so colour and brightness stay within the original calibration.
Rear card and PSU access
Receiving cards and power supplies are swapped from the rear without removing the cabinet from truss, which keeps a show running during a repair.
Spares and calibration
Spare modules, cards and locks are listed per batch. A calibration file and pixel map travel with the shipment for field replacement.
Product credibility
Documented before it ships
Rental LED Display is built on the same production line as our project walls. Cabinets, modules and control settings are recorded per batch, and the documentation travels with the shipment so the site team is not working from memory.
ISO 9001
Factory process control
CE / RoHS / FCC
Product compliance
Batch tested
Aging and calibration record
2–3 years
Standard warranty
Quality record
- CE, RoHS and FCC documentation for the supplied configuration.
- Aging and white-balance calibration record per batch.
- Cabinet drawing, pixel map and control settings in the handover pack.
- Spare modules matched to the original production batch.
Applications
Concerts & tours
Fast build and strike with road-ready cabinets.
Exhibitions
High-brightness walls for trade-show halls.
Corporate events
Clean presentation surfaces for launches.
Broadcast events
Camera-safe refresh for live coverage.
Rental selection and delivery
Build the rental inventory around the show
Rental pitch is set by the closest camera and audience position, not by the largest available cabinet. Cabinet format, curve capability and flight-case logistics then determine how fast the wall goes in and out.
Match pitch to the front row
P2.6 for close-camera stage work and front rows around 3 m; P2.9–P3.91 for corporate general sessions and festivals; P4.81 for arena walls where the nearest viewer is beyond 6 m.
Choose the cabinet for the crew
A 500 × 500 mm cabinet is easier for one-person handling and mixed layouts. A 500 × 1000 mm cabinet reduces piece count on tall portals but needs a two-person lift and more flight-case planning.
Confirm curve and rigging
Curved locks, truss clamps and safety points are selected before the show drawing is approved. Confirm whether the wall is ground-supported, flown or built into a set.
Model comparison
Compare Rental LED Display models
Pitch, power, cabinet and the job each model is specified for. Open a model to see its cabinet build, service access and quotation route.
| Model | Brightness | Avg power | Cabinet | Specified for | Detail |
|---|---|---|---|---|---|
Rental P2.6 2.604mm | 4,500 nits | ≤250 W/m² | 500 × 500 × 85mm | Concert stages · Product launches | View model |
Rental P2.9 2.976mm | 4,500 nits | ≤250 W/m² | 500 × 500 × 85mm | Corporate general sessions · Festival stages | View model |
Rental P3.91 3.91mm | 5,000 nits | ≤280 W/m² | 500 × 500 / 500 × 1000mm | Stage portals · Arena screens | View model |
Rental P4.81 4.81mm | 5,500 nits | ≤300 W/m² | 500 × 1000mm | Arena walls · Outdoor festivals | View model |
Typical values for the current series. Final brightness, power and cabinet detail are confirmed on the approved specification sheet.
Deployment playbook
Three rental builds, three priorities
A touring wall, a corporate general session and an outdoor festival place different demands on weight, brightness and changeover time.
Touring and concert stages
Crew time and road durability dominate. Shared cabinet families, recessed connectors and protected corners reduce damage and keep spare logistics simple across dates.
P2.6–P3.91 · 4,500–5,000 nits · flight cases
Corporate general sessions
The wall is close to the audience and on camera. Fine pitch, high refresh and a clean seam at the centre of the stage matter more than maximum brightness.
P2.6–P2.9 · >7680Hz · 500 × 500 mm
Outdoor festivals and arena walls
Coverage and daylight readability take priority. Larger cabinets and higher output reduce build time and hold contrast under stage wash and open-air light.
P3.91–P4.81 · 5,000–5,500 nits · 500 × 1000 mm
Delivery control
Rental dispatch and spares
Rental orders are packed as working inventory, not as a one-off installation. Cabinets, locks, spare modules and control settings are listed against the show configuration.
Handover pack
- Approved cabinet layout and pixel map
- Control settings and calibration record
- Packing list, spare list and service notes
- 1
Freeze the drawing
Approved layout, pixel map and power scheduleCabinet layout, control points, power distribution and the service direction are fixed before materials are cut. The approved drawing becomes the reference for every later check.
- 2
Match the batch
Batch record and module position listLED modules, driver ICs and power supplies are drawn from the same production batch where the order size allows, then labelled by cabinet position.
- 3
Age and calibrate
Aging log and calibration fileAssembled cabinets run through an aging cycle and white-balance calibration. Faults found at this stage are corrected before packing, not after arrival.
- 4
Pack for the route
Packing list, spare list and handover packCabinets are packed against the transport method and site access. Flight-case quantity and spare ratio are confirmed against the tour schedule and crew size.
Buyer questions
Questions we answer before quotation
These are the points that most often change the specification after the first enquiry. If your question is not here, send it with the site details.
Ask an engineer01Which pitch should a rental company stock first?
P3.91 is the most flexible starting point for corporate and festival work. P2.6 is added when close-camera stage work is part of the offer, and P4.81 for arena-scale walls where coverage matters more than fine detail.
02Can the cabinets form a curved wall?
Yes, optional curve locks allow concave or convex configurations. The curve radius and lock quantity are confirmed on the stage drawing so the seam and rigging points are planned together.
03Are flight cases included?
Flight cases can be quoted with the cabinets. The case count depends on cabinet size, spare ratio and the transport method. Standard models are packed for export when cases are not requested.
04How fast can a rental order ship?
Standard rental models are typically 5–7 working days after drawing approval and deposit. Larger inventory orders, custom colours or mixed cabinet families are scheduled on the quotation.
Next step
Plan the rental inventory
Use the application guide and project references to compare touring, corporate and outdoor rental requirements.
Sports and event guide
See how this series is specified against viewing distance, room light and installation constraints.
Open application guideInstalled references
Review project types, cabinet formats and the delivery scope used on comparable installations.
View case studiesDatasheets and drawings
Request the current specification sheet, cabinet drawing and control compatibility list.
Open downloadsTalk to an engineer
Send the wall size, viewing distance and site photos. We reply with a configuration and quotation.
Request a quotePlan your next stage build