Rental LED

Rental P4.81

Long-throw rental cabinet for large arena walls, with 5,500 nits and a 500 × 1000mm format that cuts build time.

4.81mm

Pixel pitch

5,500 nits

Brightness

>7680Hz

Refresh rate

Rental P4.81 cabinet
Rental P4.81 cabinet · 500 × 1000mm

Product overview

P4.81 is chosen when the viewing distance passes six metres and the priority shifts to coverage and speed. The 500 × 1000mm cabinet covers a square metre per piece, which reduces truss loading points and the number of locks to close on a large arena wall.

Every unit is assembled and tested in Shenzhen before packing. Cabinet drawings, pixel map and control-system settings are supplied with the shipment, so the configuration on site matches the quotation.

Arena wallsOutdoor festivalsStadium concertsLarge exhibitions

Specifications

Pixel pitch
4.81mm
Brightness
5,500 nits
Refresh rate
>7680Hz
Avg power
≤300 W/m²
Cabinet size
500 × 1000mm
Cabinet weight
12.5kg
Cabinet material
Die-cast magnesium alloy
Grayscale
16-bit
Viewing angle
160° horizontal / 140° vertical
Control system
Novastar / Colorlight compatible
Flight case
4 cabinets per case

Advantages

Engineering decisions behind Rental P4.81, and what they change on site.

01

Fewer pieces per square metre

One square metre per cabinet means half the handling steps of a 500 × 500mm build at the same wall size.

02

Daylight-capable brightness

5,500 nits keeps content legible on open-air stages and in covered venues with strong front light.

03

Rear service access

Receiving cards and power supplies are swapped from the rear without removing the cabinet from the truss.

Rental P4.81

Structure introduction

Rental P4.81 is assembled as a touring cabinet, not an installed panel. A die-cast magnesium frame carries the LED modules, receiving card and power supply as one locked unit, so the 500 × 1000mm cabinet can be handled, flown and struck repeatedly without losing alignment.

500 × 1000mm
01

Load-bearing die-cast frame

Ribs are cast into the cabinet rather than added as separate brackets. The frame keeps the module plane flat under truss load and protects the corners during freight.

02

Module and driver bay

LED modules seat into machined pockets. The receiving card and power supply sit behind a removable rear cover, separated from the module face so heat does not pass through the LED board.

03

Lock and alignment system

Tool-free locks and locating pins pull adjacent cabinets to a controlled seam. Curved locks are available for concave or convex stage shapes without changing the cabinet family.

04

Power and data path

Power and data connectors are recessed into the frame and rated for repeated mating. Cabinets can be fed from either side to suit truss layout and flight-case order.

Design details

The decisions that affect how Rental P4.81 looks, installs and stays serviceable on site.

01

Seam control at stage distance

The module plane and lock datum are machined together, so a 4 × 3m wall keeps a consistent seam instead of tightening at the centre and opening at the edges.

02

Rigging without extra steel

Top and bottom attachment points accept standard clamps and hooks. The cabinet weight of 12.5kg is kept within two-person handling for changeovers.

03

Front and rear service

Modules can be removed from the front when the wall is tight to a set, while cards and power supplies are reached from the rear when the wall is flown.

04

Road-case thinking

Connector recesses, corner protection and a shared flight-case footprint reduce damage during load-in and keep spare logistics simple across a tour.

Front maintenance

Service is planned before the wall is built. Modules, cards and power supplies are replaced from the access direction agreed on the drawing.

Front-service module design

Front module replacement

A service tool releases the module from the face. Replacement modules are batch-matched so colour and brightness stay within the original calibration.

Rear card and PSU access

Receiving cards and power supplies are swapped from the rear without removing the cabinet from truss, which keeps a show running during a repair.

Spares and calibration

Spare modules, cards and locks are listed per batch. A calibration file and pixel map travel with the shipment for field replacement.

Product credibility

Documented before it ships

Rental P4.81 is built on the same production line as our project walls. Cabinets, modules and control settings are recorded per batch, and the documentation travels with the shipment so the site team is not working from memory.

ISO 9001

Factory process control

CE / RoHS / FCC

Product compliance

Batch tested

Aging and calibration record

2–3 years

Standard warranty

Quality record

  • CE, RoHS and FCC documentation for the supplied configuration.
  • Aging and white-balance calibration record per batch.
  • Cabinet drawing, pixel map and control settings in the handover pack.
  • Spare modules matched to the original production batch.

Rental selection and delivery

Build the rental inventory around the show

Rental pitch is set by the closest camera and audience position, not by the largest available cabinet. Cabinet format, curve capability and flight-case logistics then determine how fast the wall goes in and out.

01P2.6–P4.81

Match pitch to the front row

P2.6 for close-camera stage work and front rows around 3 m; P2.9–P3.91 for corporate general sessions and festivals; P4.81 for arena walls where the nearest viewer is beyond 6 m.

02500 × 500 / 500 × 1000 mm

Choose the cabinet for the crew

A 500 × 500 mm cabinet is easier for one-person handling and mixed layouts. A 500 × 1000 mm cabinet reduces piece count on tall portals but needs a two-person lift and more flight-case planning.

03±10° curve option

Confirm curve and rigging

Curved locks, truss clamps and safety points are selected before the show drawing is approved. Confirm whether the wall is ground-supported, flown or built into a set.

Model comparison

Compare Rental P4.81 models

Pitch, power, cabinet and the job each model is specified for. Open a model to see its cabinet build, service access and quotation route.

Ask for a model recommendation
ModelBrightnessAvg powerCabinetSpecified forDetail
Rental P2.6

2.604mm

4,500 nits≤250 W/m²500 × 500 × 85mmConcert stages · Product launchesView model
Rental P2.9

2.976mm

4,500 nits≤250 W/m²500 × 500 × 85mmCorporate general sessions · Festival stagesView model
Rental P3.91

3.91mm

5,000 nits≤280 W/m²500 × 500 / 500 × 1000mmStage portals · Arena screensView model
Rental P4.81Current

4.81mm

5,500 nits≤300 W/m²500 × 1000mmArena walls · Outdoor festivalsSelected

Typical values for the current series. Final brightness, power and cabinet detail are confirmed on the approved specification sheet.

Deployment playbook

Three rental builds, three priorities

A touring wall, a corporate general session and an outdoor festival place different demands on weight, brightness and changeover time.

01

Touring and concert stages

Crew time and road durability dominate. Shared cabinet families, recessed connectors and protected corners reduce damage and keep spare logistics simple across dates.

P2.6–P3.91 · 4,500–5,000 nits · flight cases

02

Corporate general sessions

The wall is close to the audience and on camera. Fine pitch, high refresh and a clean seam at the centre of the stage matter more than maximum brightness.

P2.6–P2.9 · >7680Hz · 500 × 500 mm

03

Outdoor festivals and arena walls

Coverage and daylight readability take priority. Larger cabinets and higher output reduce build time and hold contrast under stage wash and open-air light.

P3.91–P4.81 · 5,000–5,500 nits · 500 × 1000 mm

Delivery control

Rental dispatch and spares

Rental orders are packed as working inventory, not as a one-off installation. Cabinets, locks, spare modules and control settings are listed against the show configuration.

Handover pack

  • Approved cabinet layout and pixel map
  • Control settings and calibration record
  • Packing list, spare list and service notes
Request the current datasheet
  1. 1

    Freeze the drawing

    Approved layout, pixel map and power schedule

    Cabinet layout, control points, power distribution and the service direction are fixed before materials are cut. The approved drawing becomes the reference for every later check.

  2. 2

    Match the batch

    Batch record and module position list

    LED modules, driver ICs and power supplies are drawn from the same production batch where the order size allows, then labelled by cabinet position.

  3. 3

    Age and calibrate

    Aging log and calibration file

    Assembled cabinets run through an aging cycle and white-balance calibration. Faults found at this stage are corrected before packing, not after arrival.

  4. 4

    Pack for the route

    Packing list, spare list and handover pack

    Cabinets are packed against the transport method and site access. Flight-case quantity and spare ratio are confirmed against the tour schedule and crew size.

Buyer questions

Questions we answer before quotation

These are the points that most often change the specification after the first enquiry. If your question is not here, send it with the site details.

Ask an engineer
01Which pitch should a rental company stock first?

P3.91 is the most flexible starting point for corporate and festival work. P2.6 is added when close-camera stage work is part of the offer, and P4.81 for arena-scale walls where coverage matters more than fine detail.

02Can the cabinets form a curved wall?

Yes, optional curve locks allow concave or convex configurations. The curve radius and lock quantity are confirmed on the stage drawing so the seam and rigging points are planned together.

03Are flight cases included?

Flight cases can be quoted with the cabinets. The case count depends on cabinet size, spare ratio and the transport method. Standard models are packed for export when cases are not requested.

04How fast can a rental order ship?

Standard rental models are typically 5–7 working days after drawing approval and deposit. Larger inventory orders, custom colours or mixed cabinet families are scheduled on the quotation.

Request Rental P4.81 pricing and drawings

Send viewing distance, wall size and installation type. We reply with cabinet quantity, control layout and a quotation within 24 business hours.

  • Factory-direct pricing
  • CE / RoHS / FCC / ISO 9001
  • 5–7 day lead time for standard models
粤ICP备2026050467号-1